Vertiv Debuts Liebert XDU With Drop-In Liquid Cooling for Data Centers

Nov. 27, 2019
Vertiv is making it easier for customers to transition from air-cooled data centers to liquid cooling with the introduction of the Liebert XDU, a 60kW liquid-to-air cooling distribution unit. The new offering supports retrofits of existing facilities to support high-density zones.

Vertiv is making it easier for customers to transition from air-cooled data centers to liquid cooling with the introduction of the Liebert XDU, a 60kW liquid-to-air cooling distribution unit. The new offering arrives as a growing number of data center users struggle to manage high-density workloads and the associated thermal challenges.

Vertiv said the development of the Liebert XDU was motivated by the growing number of high-performance computing applications such as data analytics and machine learning, which are pushing rack densities and temperatures beyond the limits of most air-cooled solutions. The Liebert XDU enables users to deploy liquid-cooled server applications into any data center environment. The system is available currently in North America.

“High performance computing applications are growing, and they present new thermal management challenges for our customers,” said John Schneider, senior vice president, thermal management at Vertiv. “Colocation providers who have relied on air cooling for their facilities are now hosting clients with applications with higher power processors that require liquid cooling. With the Vertiv Liebert XDU, our customers can meet that demand without expensive retrofits or disruption to their existing operations.”

The XDU is an expansion of the Liebert XD line of refrigerant-based cooling solutions, which previously offered air cooling modules for hot aisle/cold aisle data center designs. The Liebert XDU can “drop in” to an existing row, and circulates water through liquid-cooled server racks, rejecting the heat from the returning warm water into the data center’s hot aisle. It uses a closed water loop and requires no new plumbing, making the Liebert XDU an easy retrofit in existing data centers. The compact system can also be placed along the room’s perimeter.

“A liquid cooling solution such as the Liebert XDU is a compelling option because it delivers the advantages and efficiencies of liquid cooling without a complete data center retrofit,” said Jennifer Cooke, research director, cloud to edge data center trends for IDC.

This retrofit capability is attractive to companies with on-premises data centers, as it supports equipment refreshes to add more powerful servers. Colocation providers could benefit from the ability to more easily create high-density water-cooled zones within an air-cooled facility.

Vertiv says it developed the Liebert XDU in close consultation with data center operators and server manufacturers, including Lenovo, which demonstrated the use of the XDU with its Neptune water-cooled server at its booth at the recent SC19 supercomputing conference.

About the Author

Rich Miller

I write about the places where the Internet lives, telling the story of data centers and the people who build them. I founded Data Center Knowledge, the data center industry's leading news site. Now I'm exploring the future of cloud computing at Data Center Frontier.

Sponsored Recommendations

Optimizing AI Infrastructure: The Critical Role of Liquid Cooling

In this executive brief, we discuss the growing need for liquid cooling in data centers due to the increasing power demands of AI and high-performance computing. Discover how ...

AI-Driven Data Centers: Revolutionizing Decarbonization Strategies

AI hype has put data centers in the spotlight, sparking concerns over energy use—but they’re also key to a greener future. With renewable power and cutting-edge cooling, data ...

Bending the Energy Curve: Decoupling Digitalization Trends from Data Center Energy Growth

After a decade of stability, data center energy consumption is now set to surge—but can we change the trajectory? Discover how small efficiency gains could cut energy growth by...

AI Reference Designs to Enable Adoption: A Collaboration Between Schneider Electric and NVIDIA

Traditional data center power, cooling, and racks aren’t sufficient for GPU-based servers arranged in high-density AI clusters...

Courtesy of Stream Data Centers
Image courtesy of Stream Data Centers

The Rise of the “Fake” Data Center Developer — And How to Tell the Difference

Stream Data Centers’ Co-Managing Partners expand on the problem of “fake” data center developers and explain how investors and end users can separate the wheat from the chaff....

White Papers

Get the full report.

Top 10 Ways to Drive Data Center Automation

July 8, 2022
Sunbird explores 10 ways in which innovative and sophisticated customers use DCIM software to drive data center automation.